Capability:
Provides the average remaining wall thickness measurement within the interrogated area (footprint). Direct contact is not required and wall thickness can be measured through any non-conductive material up to 150mm thick, e.g. insulation material, paint, bitumen, dirt, ice or sludge Works through Stainless Steel and Aluminum sheeting less than or equal to 1mm Surface preparation is not required enabling measurements to be taken through corrosion products Wide temperature range -100°C to 550°C Good reproducibility of PEC readings at the same locations makes it ideal for corrosion monitoring Rope Access deployable Subsea and splash zone deployable Battery operated and robust design Fast and reliable data collection typically 700 to 1000 readings per day.